CLEANING/INSPECTION
46.
Clean tubes (7,14,21,26,35 and 43)
with warm water and detergent.
W A R N I N G
l TOXIC/FLAMMABLE
Dry cleaning solvent P-D-680 used
for cleaning parts, is toxic and
f l a m m a b l e . U s e o n l y i n w e ll
ventilated areas. Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent is
u s e d o r s t o r e d . A v o i d c o n t a ct
w i t h e y e s , s k i n o r c l o t h i n g . If
contact with eyes is made, flush
with cold water and seek medical
attention immediately. If contact
with skin or clothing is
made,
flush with cold water.
I f y o u
become dizzy while using cleaning
s o l v e n t , g e t
f r e sh
a ir
immediately.
l COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
U s e o n l y w i t h e f f e c t i v e c h i p
guarding and personal protective
equipment
( g o g g l e s / s h i e l d,
g l o v e s , e t c . ).
47.
Clean all other parts with cleaning
solvent P-D-680.
Dry thoroughly
with compressed air.
R e f e r t o
paragraph 2-8.
Go to sheet 8
8-80
|