TM 10-3930-643-20
BRAKE SYSTEM TROUBLESHOOTING AND MAINTENANCE.
8 - 7.
Pressure Converter Breather (S/N 2001 and above). (Sheet 4 of 5)
CLEANING/INSPECTION
8. Clean tube (8) with mild detergent
and water solution. Wipe dry with
clean cloth.
TOXIC/FLAMMABLE
Dry cleaning
solvent P-D-680,
used for cleaning parts, is toxic
and flammable.
Use only in well
ventilated
areas.
Wear
protective goggles and gloves.
Do not smoke or allow open flames
or sparks in areas where cleaning
solvent is used or stored.
Avoid
contact
w i t h e y e s,
s k i n o r
c l o t h i n g.
If contact with eyes
is made,
flush with cold water
and
seek
medical
attention
immediately.
I f c o n t a c t w i th
skin or clothing is made, flush
with cold water.
If you become
d i z z y w h i l e u s i n g c l e a n i ng
s o l v e n t,
g et
f r e s h a ir
immediately.
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
U s e o n l y w i t h e f f e c t i v e c h ip
guarding and personal protective
equipment (goggles/shield,
g l o v e s , e t c . ).
9.
Clean all other parts with cleaning
solvent P-D680.
Dry thoroughly
w i t h c o m p r e s s e d a i r . R e f e r to
paragraph 2-8.
10.
Inspect tube (8) for cracks or block-
age.
Replace if cracked or blocked.
If replacement is required, cut bulk
hose to a length of 29 inches.
Left
and right side hoses are the same
length.
11.
Inspect all parts.
R e f e r t o p a r a-
graph 2-9.
Go to sheet 5
8-23
|