TM 10-3930-643-20
BRAKE TROUBLESHOOTING AND MAINTENANCE. (cont)
8 - 6.
Power Cluster Breather (S/N 2000 and below). (Sheet 4 of 5)
CLEANING/Inspection
8.
Clean tube (8) with mild detergent
and water solution.
W A R N I N G
g TOXIC/FLAMMABLE
Dry cleaning
solvent P-D-680,
used for cleaning parts, is toxic
and flammable.
Use only in well
v e n t i l a t e d a r e a s.
Wear
protective goggles and gloves.
Do not smoke or allow open flames
or sparks in areas where cleaning
solvent is used or stored.
Avoid
c o n t a c t w i t h e y e s,
s k i n o r
c l o t h i n g.
If contact with eyes
is made, flush with cold water
and
seek medical
attention
immediately.
I f c o n t a c t w i t h
skin or clothing is made,
f l u sh
with cold water.
If you
become
d i z z y w h i l e u s i n g c l e a n i ng
s o l v e n t , g et
fresh
a ir
immediately.
l COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
U s e o n l y w i t h e f f e c t i v e c h ip
guarding and personal protective
equipment
( g o g g l e s / s h i e l d ,
g l o v e s , e t c . ) .
9 .
10.
11.
Go to
8-18
C l e a n a l l p a r t s w i t h c l e a n i ng
solvent P-D-680.
Dry thoroughly
with compressed air.
R e f e r t o
paragraph 2-8.
I n s p e c t t u b e ( 8 ) f o r c r a c k s o r
b l o c k a g e . R e p l a c e i f c r a c k e d or
blocked.
I f r e p l a c e m e n t is
required, cut from
b u l k t u b i n g.
Length for right side power cluster
is 38 inches.
Length for left side
power cluster is 26 inches.
Inspect all other
paragraph 2-9.
sheet 5
p a r t s.
R e f e r t o
|