TM 10-3930-643-20
GENERAL MAINTENANCE PROCEDURES. (cont)
2-13.
Electrical Repair. (cont)
(2) Connector with ring-type terminals.
DISASSEMBLY
Cut wire close to terminal.
Remove and discard terminal.
ASSEMBLY
NOTE
New terminal must be selected to match the ring size of the terminal
with the mounting screw at the connection.
New terminal must also
match crimp tabs with the thickness of the wire.
1.
2.
3.
4.
5.
Strip wire, refer to Wire Size Chart.
Do not nick or cut strands.
Tin bare wires. Use resin-core solder to coat bare wires.
If using solid
core solder, clean wires with flux before tinning.
Insert wire into new terminal.
Crimp new terminal.
Securely fasten wire to new crimp-type, insulated new
terminal.
Secure wire to prevent movement and solder new solder-type terminal. Use
solder sparingly.
2-16
|