TRANSMISSION  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 6-6. Transmission   Breather.   (Sheet  2  of  4) REMOVAL 1. 2. 3. 4. 5. 6. Open   door   (1)   in   right   side   of   ether start   compartment. Using   a   9/16"   socket,   socket   wrench handle   and   9/16"   open   end   wrench, remove   locknut   (2),   clamp   (3)   and b o l t    ( 4 ). Using  snap r i n g    p l i e r s ,    1 - 1 / 8 " , 1-1/16"   and   5/8"   open   end   wrenches, remove   breather   (5),   coupling (6) and   reducer   (7). Using   side   cutting   pliers,   cut   and discard   two   tie   straps   (8). NOTE Tag   all   hose   and   tube   assemblies before   disconnecting   to   aid   in i n s t a l l a t i o n. Remove  hose  assembly  (9). U s i n g    s n a p    r i n g    p l i e r s ,    5 / 8 "    a nd 11/16"   open   end   wrenches,   remove reducer   (10)   and   elbow   (11). Go  to  sheet  3 6-34