TM 10-3930-643-20
TRANSMISSION TROUBLESHOOTING AND MAINTENANCE. (cont)
6-3. Torque Converter High Pressure Regulator Valves. (Sheet 5 of 8)
DISASSEMBLY (cont)
15.
Using a 1-1/4" open end wrench,
r e m o v e p l u g ( 2 8 ) , g a s k e t ( 2 9 ),
spring (30), spring (31) and piston
(32) from valve body (27). Discard
g a s k e t ( 2 9 ) . R e m o v e a l l g a s k et
material from mounting surfaces.
CLEANING/INSPECTION
WARNING
TOXIC/FLAMMABLE
Dry cleaning solvent P-D-680 used
for cleaning parts, is toxic and
f l a m m a b l e . U s e o n l y i n w e ll
ventilated areas. Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent is
u s e d o r s t o r e d . A v o i d c o n t a ct
w i t h e y e s , s k i n o r c l o t h i n g . I f
contact with eyes is made, flush
with cold water and seek medical
attention immediately. If contact
with skin or clothing is
made,
flush with cold water.
I f y o u
become dizzy while using cleaning
s o l v e n t , g et
fresh
a i r
immediately.
16.
C l e a n a l l p a r t s w i t h c l e a n i ng
solvent P-D-680.
with clean cloth.
graph 2-8.
17.
Inspect all parts.
graph 2-9.
Dry thoroughly
R e f e r t o p a r a-
R e f e r t o p a r a-
Go to sheet 6
6-18
|