TM   10-3930-643-20 GENERAL  MAINTENANCE  PROCEDURES. 2-13. Electrical    Repair.    (cont) (cont) (a)   AN/URM-105. Set   meter   switch   to   DC volts   range.   (To   measure   24   volts   DC,   set   switch on   100   DC   volts   range). (b)   TS-352   B/U. 1   Set   FUNCTION   switch   (1)   to   DIRECT. 2   Put   black   lead   (2)   in   LHMS-IXY3   AC j a c k. 3  To  measure  24 lead   (3)   into o f    m e t e r .    ( If volts   DC.   use less   than   2.5 j a c k ). v o l t s    D C ,    p l u g    r ed 50V   jack   on   left   side measuring   less   than   10 10V   jack.   If   measuring volts   DC. u s e    2 . 5V (5)   Measuring   DC   voltage.   To   measure   DC   voltage,   do   the   following   steps: (a)   Set   up   and   zero   multimeter. C A U T I ON If   you   are   unsure   of   the   voltage   to   be measured   on   the   vehicle,   always s t a rt on   the   highest   range. T h i s    w i l l    p r o - tect   the   meter. (b)   Connect   the   red   probe   to   the   posi- tive   (+)   side   of   the   circuit   and   the   black   probe to   the   negative   (-)   side. The   example   shows   24 volts   DC   being   measured   across   the   batteries. (c)   Read   the   meter.   If   the   needle   moves off   scale   to   the   left,   reverse   the   probes   on   the c i r c u i t. 2-12