TM 10-3930-643-20
ELECTRICAL SYSTEM
5-48.
Batteries.
INSTALLATION
TROUBLESHOOTING AND MAINTENANCE. (cont)
(Sheet 6 of 7)
17.
18.
19.
20.
21.
22.
Keep batteries in upright
position during installation.
Place clean cloth over battery vent
plugs on batteries (15 and 16).
Using two personnel, a forklift and
a pallet, place batteries (15 and 16)
on pallet and raise pallet up to
fender level.
Slide batteries into
compartment.
Using a 9/16 open end wrench,
i n s t a l l t w o h o o k s ( 1 4 ) b r a c k e ts
(13), washers (12) and nuts (11).
Using a 1/2 open end wrench,
connect battery ground cable
( 1 0 ).
Apply silicone sealant over entire
connection.
Connect battery positive cable (9).
Apply silicone sealant over entire
connection.
Connect battery cable (8).
Apply
s i l i c o ne
sealant
o v er
e n t i re
connection.
Go to sheet 7
5-234
|