TM 10-3930-643-20
ELECTRICAL SYSTEM TROUBLESHOOTING AND MAINTENANCE. (cont)
5-44.
Low Air Pressure Switch. (Sheet 2 of 2)
REMOVAL (cont)
4.
Disconnect wire assembly (5).
5.
Using a 3/4 open end wrench, remove
reducer (6) and low
a i r p r e s s u r e
switch (7).
CLEANING/INSPECTION
6.
Clean all parts with mild detergent
and water solution. Wipe dry with
clean cloth.
R e f e r t o p a r a g r a ph
2-8.
7.
I n s p e c t a l l p a r t s . R e f e r t o p a r a-
graph 2-9.
INSTALLATION.
8.
9.
10.
11.
12.
Using a 3/4 open end wrench,
install low air pressure switch (7)
and reducer (6).
Connect wire assembly (5).
U s i n g a f l a t t i p s c r e w d r i v e r ,
install screw (4) and secure
wire
assembly (5) on low
a i r p r e s s u re
switch (7).
Position instrument panel
(3)
in
h o u s i n g i n f r o n t o f o p e r a t o r s
compartment.
U s i n g a c r o s s t i p s c r e w d r i v e r,
install four washers (2) and screws
( 1 ).
NOTE
Return M10A Forklift to original
equipment condition.
END OF TASK
5-216
|