5-42.
Torque Converter Temperature Sender and Switch. (Sheet 4 of 4)
INSTALLATION
10.
Using a 15/16 open end wrench,
install sending unit (6) on torque
converter.
1 1 . C o n n e c t w i re
a s s e m b l y ( 5 ) at
terminal.
12.
U s i n g a f l a t t i p s c r e w d r i v e r ,
i n s t a l l s c r e w ( 4 ).
A p p l y s i l i c o n e
sealant over entire connection.
13.
Using a 7/8 open end wrench,
i n s t a l l
switch
( 3 ) o n t o r q u e
converter.
14.
Connect wire
a s s e m b l y ( 2 ) a t
terminal.
15.
U s i n g a f l a t t i p s c r e w d r i v e r,
i n s t a l l s c r e w ( 1 ) . A p p l y s i l i c o n e
sealant over entire connection.
NOTE
Return M10A Forklift to original
equipment condition.
END OF TASK