TM 10-3930-643-20
ELECTRICAL SYSTEM TROUBLESHOOTING AND MAINTENANCE.
5-11.
Starter Lockout Relays. (Sheet 5 of 5)
TESTING
22.
23.
24.
25.
26.
27.
28.
Test winding resistance of relay (7)
on right side of frame in
engine
compartment.
Connect red lead on multimeter to
terminal (18) and black lead to
terminal (19).
Observe needle movement. Range for
winding resistance is between
200
and 250 ohms.
Replace if test is not within range
l i m i t s .
Reconnect batteries.
Apply silicone sealant over entire
c o n n e c t i o n s o f w i r e a s s e m b l i es
(9,8,3 and 2) on right side of frame
in engine compartment.
Install engine side access cover (1)
on right side of engine compartment,
refer to paragraph 12-4. Close latches.
NOTE
Return M10A Forklift to original
equipment condition.
END OF TASK
5-97
|