TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-11. Starter   Lockout   Relays.   (Sheet   3   of   5) INSTALLATION 8. Using   a   7/16”   open   end   wrench,   7/16” socket  and  socket wrench   handle, install   relay   (13),   two   bolts   (12), lock   washers   (11)   and   nuts   (10)   on right   side   of f r a m e    i n    e n g i ne compartment. 9. Connect   wire   assemblies   (9   and   8). 10. Install   relay   (7),   two   bolts   (6), lock   washers   (5)   and   nuts   (4). 11. Connect   wire   assemblies   (3   and   2). TESTING Before   proceeding   with   electrical test,   refer   to   Chapter 2 for i n i t i a l setup i n s t r u c t i o n s. Failure   to   follow   this   procedure could   cause   damage   to   equipment. NOTE The   following   is   a   test   procedure for   one   starter   lockout r e l a y . T h e    t e s t    p r o c e d u r e    f o r    t h e remaining   starter   lockout relay i s    i d e n t i c a l . 12. 13. 14. Using   1/2”   open   end   wrench,   connect battery   negative   cable. Test   upper   contact   opening   voltage on   relay   (7)   on   right   side   of   frame in   engine   compartment. Connect   red   lead   on   multimeter   to terminal   (14)   and   black   lead   to terminal   (15). Go  to  sheet  4 5-95

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business