TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-8. Instrument   Panel   Troubleshooting.   (cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION x. FORKS WILL NOT OSCILLATE OR SEPARATE. NOTE Before   proceeding   with   continuity   tests,   refer   to   paragraph   2-13   for i n i t i a l    s e t u p    i n s t r u c t i o n s. Step   1. Test   the   continuity   of   the   fork   control   switch. Disconnect harness   assembly   from   the   switch.   Connect   multimeter   to   the switch   terminals. Turn   switch   to   both   positions. If   the   multimeter   needle   does   not   move,   the   switch   does   not   have c o n t i n u i t y. Replace   switch,   refer   to   paragraph   5-30. Step   2. Test   the   continuity   of   wire   assembly.   Disconnect   wire   assembly from   switch. Connect   multimeter   to   wire   assembly. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y. I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. Step   3. Return   M10A   Forklift   to   original   equipment   condition. 5-76