TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-8. Instrument   Panel   Troubleshooting.   (cont) MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION v . ETHER  START  SWITCH  DOES  NOT  OPERATE.  (cont) Step   4. Test   the   continuity   of   the   ether   starting   valve.   Connect multimeter   to   terminals   at   the   bottom   of   ether   starting   aid. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   ether   starting   aid,   refer   to   paragraph   4-24. Step   5. Test   the   continuity   of   the   wire   assembly.   Disconnect   Terminal D   from   ether   starting   valve,   as   shown.   Disconnect   main   harness from   intermediate   harness,   as   shown.   Connect   multimeter   to Terminal   D   and   Pin   K. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. 5-74