TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5 - 8. Instrument    Panel    Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION v.  ETHER  START  SWITCH  DOES  NOT  OPERATE. Step   2. Test   the   continuity   of   the   wire   assembly.   Disconnect   Terminal A   from   ether   start   switch,   as   shown.   Disconnect   harness assembly   at   Connector   B   from   start   switch,   as   shown. Connect multimeter   to   Terminal   A   and   Connector   B. If    the    multimeter    needle    does    not    move,    the    circuit    does    not    have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. Step   3. Test   the   continuity   of   the   wire   assembly.   Disconnect   Terminal C   from   ether   start   switch,   as   shown. Disconnect instrument panel   harness   from   intermediate   harness,   as   shown. Connect multimeter   to   Terminal   C   and   Pin   K. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y. I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. 5-73