TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-8. Instrument    Panel    Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION r. START SWITCH DOES NOT OPERATE. Step   2. Test   the   continuity   of   the   wire   assembly.   Disconnect   harness assembly   at   Connector   A from s t a rt s w i t c h ,    as shown. Disconnect   instrument   panel   harness   from   intermediate   harness, as   shown.   Connect   multimeter   to   Connector   A   and   Pin   L. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y . I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. Step  3. Return   M10A   Forklift   to   original   equipment   condition. s . ENGINE  FAN  OFF  SWITCH  DOES  NOT  OPERATE. NOTE Before   proceeding   with   continuity   tests,   refer   to   paragraph   2-13   for i n i t i a l    s e t u p    i n s t r u c t i o n s . Step   1. Test   the   continuity   of   the   engine   fan   off   switch.   Turn   switch to   ON   position. Connect   multimeter   to   terminals   at   the   back   of switch. 5-69