TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-8. Instrument   Panel   Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION o. HOURMETER DOES NOT OPERATE. NOTE Before   proceeding   with   continuity   tests,   refer   to   paragraph   2-13   for i n i t i a l    s e t u p    i n s t r u c t i o n s. Step   1. Test   the   continuity   of assembly   at   Connectors to   both   connectors. the   hourmeter   gage. Disconnect   harness A   and   B,   as   shown. Connect multimeter If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   hourmeter,   refer   to   paragraph   5-14. Step   2.   Test   the   continuity   of   the   wire   assembly.   Disconnect   Terminal E   from   circuit   breaker,   as   shown. Connect m u l t i m e t e r    to Connector  C  and  Terminal  E. If   the   multimeter   needle c o n t i n u i t y. Identify   as Support. Step   3. Test   the   continuity instrument   panel   harness   from   the   intermediate   harness,   as shown.   Connect   multimeter   to   Connector   D   and   Pin   A. does   not   move,   the   circuit   does   not   have a   defective wire and c o n t a c t    D i r e ct of  the  wire  assembly. D i s c o n n e c t    t he If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. 5-63