TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-8. Instrument   Panel   Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION m.  FUEL  LEVEL  GAGE  DOES  NOT  OPERATE. Step   5. Test   the   continuity   of   the   fuel   level   sending   unit.   Connect multimeter   to   sending   unit   terminal   and   ground. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y .    R e p l a c e    f u e l    l e v e l    s e n d i n g    u n i t ,    r e f e r    t o    p a r a g r a ph 5-43. Step   6. Test   the   continuity   of   the   wire   assembly.   Disconnect   main harness   from   intermediate   harness,   as   shown.   Connect multimeter   to   terminal   and   Pin   D. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity. I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e c t Support. Step   7. Return   M10A   Forklift   to   original   equipment   condition. 5-61