5-8.
Instrument Panel Troubleshooting. (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
l .
TORQUE CONVERTER TEMPERATURE GAGE WILL NOT OPERATE. (cont)
Step 3.
Test the continuity of the wire assembly. Disconnect twelve
pin connector from instrument panel, as shown. Disconnect
instrument panel harness from intermediate harness, as shown.
Connect multimeter to Pin 1 and Pin B.
If the multimeter needle does not move, the circuit does not have
c o n t i n u i t y . I d e n t i f y a s a d e f e c t i v e w i r e a n d c o n t a c t D i r e ct
Support.
Step 4.
Test the continuity of the torque converter temperature sender.
Connect multimeter to sending unit terminal and ground.
If the multimeter needle does not move, the circuit does not have
continuity. Replace torque converter temperature sender, refer to
paragraph 5-42.
5-58
|