TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-8. Instrument   Panel   Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION l . TORQUE  CONVERTER  TEMPERATuRE  GAGE  WILL  NOT  OPERATE. NOTE Before   performing   continuity   tests,   refer   to   paragraph   2-13   for initial    setup    instructions. Step   1. Remove   bezel   assembly   and   torque   converter   temperature   gage. Test   the   continuity   of   gage.   Connect   multimeter   to   terminals in   the   back   of   gage. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have Continuity.   Replace   torque   converter   temperature   gage,   refer   to paragraph   5-17. Step  2. Connect   instrument   gage   tester.   Use   instructions   provided   with gage   tester.   Test   values   for   torgue   converter   temperature   gage s h o u l d    r e a d :    R u n    ( g r e e n )    z o n e ,    L o w    1 4 0 ° F ,    H i g h    2 5 0 ° F . Resistance   (ohms),   1828   210.   System   voltage,   24V. 5-57