TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-8. Instrument   Panel   Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION j  . TORQUE CONVERTER OIL TEMPERATURE WARNING LIGHT DOES NOT OPERATE. If   the   multimeter   needle   does   not   move,   the   switch   does   not   have continuity.   Replace   the   switch.   Refer   to   paragraph   5-42. NOTE Before   proceeding   with   continuity   test,   refer   to   paragraph   2-13   for i n i t i a l    s e t u p    i n s t r u c t i o n s. Step  3. Test   the   continuity   of   the   wire   assembly.   Disconnect   twelve pin   connector   from   instrument   panel,   as   shown.   Disconnect instrument   panel   harness   from   intermediate   harness,   as   shown. Connect   multimeter   to   Pin   11   and   Pin   Z. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have c o n t i n u i t y . I d e n t i f y    a s    a    d e f e c t i v e    w i r e    a n d    c o n t a c t    D i r e ct Support. Step   4. Return   M10A   Forklift   to   original   equipment   condition. 5-53