TM 10-3930-643-20
ELECTRICAL SYSTEM TROUBLESHOOTING AND MAINTENANCE. (cont)
5-8.
Instrument Panel Troubleshooting. (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
i .
BRAKE PRESSURE WARNING LIGHT REMAINS ON.
Step 1.
Reset indicator rod.
Push indicator rod back in place with a length of wire. The
indicator rod has no resistance and the light will go off.
Step 2.
Return M10A Forklift to original equipment condition.
j. TORQUE CONVERTER OIL TEMPERATURE WARNING LIGHT DOES NOT OPERATE.
Step 1.
Remove socket and check torque converter oil temperature
warning light bulb.
If bulb is burned out, replace, refer to paragraph 5-25.
Step 2.
Test continuity of the torque converter oil temperature warning
light switch.
Disconnect the wire assembly, as shown. Connect
multimeter to switch terminal and ground.
5-52
|