TM 10-3930-643-20
ELECTRICAL SYSTEM TROUBLESHOOTING AND MAINTENANCE. (cont)
5-8.
Instrument Panel Troubleshooting. (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3.
Test the continuity of the wire assembly. Disconnect twelve
pin connector from instrument panel, as shown. Disconnect
instrument panel harness from intermediate harness, as shown
Connect multimeter to Pin 9 and Pin C.
Step 4.
Return M10A Forklift to original equipment condition.
e. GROUND DRIVEN STEERING WARNING LIGHT DOES NOT OPERATE.
5-44
Step 1.
Remove socket and check ground
bulb.
If the bulb is burned out, replace,
NOTE
driven steering warning light
refer to paragraph 5-25.
Before proceeding with continuity test, refer to paragraph 2-13 for
i n i t i a l s e t u p i n s t r u c t i o n s.
Step 2.
Test the continuity of the ground driven steering warning light
switch. Disconnect the wire harness assembly from side of
switch. Connect multimeter to the switch terminal.
|