TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-8. Instrument   Panel   Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION a.  LOW  AIR  PRESSURE  WARNING  LIGHT  DOES  NOT  OPERATE. Step   1. Check   the   low   air   pressure   warning   light   bulb. If   the   bulb   is   burned   out,   replace,   refer   to   paragraph   5-22. NOTE Before   proceeding   with   continuity   tests,   refer   to   paragraph   2-13   for i n i t i a l    s e t u p    i n s t r u c t i o n s. Step   2. Test   the   continuity   of   the   low   air   pressure   warning   light assembly.   Disconnect   harness   assembly   at   Connectors   A   and   B, as   shown.   Connect   multimeter   to   both   connectors. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   low   air   pressure   warning   light   assembly,   refer to   paragraph   5-22. 5-39