TM 10-3930-643-20
ELECTRICAL SYSTEM TROUBLESHOOTING AND MAINTENANCE.
5-7.
Light System Troubleshooting.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a.
FRONT WORK LIGHT(S) DOES NOT OPERATE.
Step 6.
Test the light switch for continuity.
Disconnect instrument
panel harness from light switch, as shown. Turn light switch
to ON position.
Connect the multimeter to Pin M and to ground.
If the multimeter needle does not move, the circuit does not have
continuity. Replace light switch, refer to paragraph 5-27.
Step 7.
Return M10A Forklift to original equipment condition.
b .
HEADLIGHT(S) DOES NOT OPERATE.
Step 1.
Check the bulb.
If the headlight bulb is burned out, replace, refer to paragraph
5-34.
Before proceeding with continuity test, refer
i n i t i a l s e t u p i n s t r u c t i o n s.
to paragraph 2-13. for
5-27
|