TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 5-7.   Light   System   Troubleshooting. MALFUNCTION TEST OR INSPECTION CORRECTIVE   ACTION a. FRONT WORK LIGHT(S) DOES NOT OPERATE. WARNING Always   disconnect   battery   ground   cable   before   working   on   electrical components   of   this   equipment. DEATH or   SEVERE   INJURY   may   result   if   you   fail   to   observe   this   procedure.   If you   receive   an   electrical   shock,   seek   medical   help. Step   1. Remove   retainer   and   check   the   bulb. I f    t h e    f r o n t    w o r k    l i g h t    b u l b    i s    b u r n e d    o u t ,    r e p l a c e ,    r e f e r    to paragraph   5-34. N O TE Before   proceeding   with   continuity   test,   refer   to   paragraph   2-13.e.   for i n i t i a l    s e t u p    i n s t r u c t i o n s. Step   2.   Test   the   continuity   of   the   work   light   assembly. Connect   the multimeter   to   terminal   at   the   back   of   light   housing a n d    to ground. If   the   multimeter   needle   does   not   move,   the   circuit   does   not   have continuity.   Replace   work   light   assembly,   refer   to   paragraph   5-34. Step   3. Test   the   continuity   of   the   wire   assembly. Disconnect   two   pin connector   from   instrument   panel   harness,   as   shown. Connect   the multimeter   to   Terminal   A   and   to   connector   pin. 5-25