ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-6. Charging   System   STE/ICE   Tests. TM   10-3930-643-20 c.  TEST  82. ALTERNATOR/GENERATOR OUTPUT VOLTAGE 1. Refer   to   VTM-General   Setup   and   Checkout   Instructions   in   TM   9-4910- 571-12&P. Connect   power   cable   to   battery. 2. Push   sleeve   back   to   expose   terminals, as  shown. Connect   positive   cable clip   to   terminal   and   negative   cable   clip   to   ground. Make   sure   electrical connections   are   clean, refer   to   paragraph   2-13. 3. Perform  test  using  TEST  89  procedure  as  instructed  in  TM  9-4910-571-12&P. 4. Test   results   should   not   exceed   a   minimum   of   26   volts,   a   norm   of   28   volts and  a  maximum  of  30  volts. 5. Return   M10A   Forklift   to   original   equipment   condition. 5-21

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business