ELECTRICAL SYSTEM TROUBLESHOOTING AND MAINTENANCE.
5-6.
Charging System STE/ICE Tests.
TM 10-3930-643-20
c. TEST 82.
ALTERNATOR/GENERATOR OUTPUT VOLTAGE
1.
Refer to VTM-General Setup and Checkout Instructions in TM 9-4910-
571-12&P.
Connect power cable to battery.
2.
Push sleeve back to expose terminals,
as shown.
Connect positive cable
clip to terminal and negative cable clip to ground.
Make sure electrical
connections are clean,
refer to paragraph 2-13.
3.
Perform test using TEST 89 procedure as instructed in TM 9-4910-571-12&P.
4.
Test results should not exceed a minimum of 26 volts, a norm of 28 volts
and a maximum of 30 volts.
5.
Return M10A Forklift to original equipment condition.