TM   10-3930-643-20 ELECTRICAL  SYSTEM  TROUBLESHOOTING  AND  MAINTENANCE. 5-4 l Starting   System   STE/ICE   Tests. a.   TEST   68. STARTER  MOTOR  VOLTAGE. 1. Refer   to   VTM-General   Setup   and   Checkout   Instructions   in   TM   9-4910- 571-12&P. Connect   power   cables   to   battery. 2. Disconnect   wire   lead   to   fuel   solenoid,   refer   to   paragraph   4-2. 3. Attach   cable   clips,   as   shown.   Ground   negative   cable   clip   to   battery. Make   sure   that   electrical   contacts   are   clean,   refer   to   paragraph   2-13. 4. Perform  test  using  procedure  TEST  89  as  instructed  in  TM  9-4910-571-12&P. 5. Test   results   should   be   24   volts. 6. Apply   silicone   sealant,    refer   to   paragraph   2-12.b. 7 . Return   M10A   Forklift   to   original   equipment   condition. 5-13