TM 10-3930-643-20
ELECTRICAL SYSTEM TROUBLESHOOTING AND MAINTENANCE.
5-4 l
Starting System STE/ICE Tests.
a. TEST 68.
STARTER MOTOR VOLTAGE.
1.
Refer to VTM-General Setup and Checkout Instructions in TM 9-4910-
571-12&P.
Connect power cables to battery.
2.
Disconnect wire lead to fuel solenoid, refer to paragraph 4-2.
3.
Attach cable clips, as shown. Ground negative cable clip to battery.
Make sure that electrical contacts are clean, refer to paragraph 2-13.
4.
Perform test using procedure TEST 89 as instructed in TM 9-4910-571-12&P.
5.
Test results should be 24 volts.
6.
Apply silicone sealant, refer to paragraph 2-12.b.
7 .
Return M10A Forklift to original equipment condition.