TM 10-3930-643-20
ELECTRICAL SYSTEM TROUBLESHOOTING AND MAINTENANCE. (cont)
5-3.
Starting System Troubleshooting. (cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b .
STARTER CRANKS TOO SLOWLY.
NOTE
Before proceeding with continuity test, refer to paragraph 2-13 for
i n i t i a l s e t u p i n s t r u c t i o n s.
Step 1.
Inspect connections of batteries to insure that they are clean
and secure.
If connections of batteries need cleaning or securing,
r e f e r t o
paragraph 2-13.
Step 2.
Test battery voltage, refer to paragraph 2-13.
If battery voltage is low, refer to TM 9-6140-200-14.
Step 3.
Inspect electrical connections at starter to insure that they
are clean and secure.
If connections need cleaning or securing, refer to paragraph 2-13.
Step 4.
Return M10A Forklift to original equipment condition.