TM 10-3930-643-20
ENGINE, FUEL, EXHAUST AND COOLING TROUBLESHOOTING AND MAINTENANCE. (cent)
4-9.
Oil Drain Line and Fittings. (Sheet 3 of 4)
CLEANING/INSPECTION
6.
Clean hose (4) with mild detergent
and water solution. Wipe hose clean
with clean cloth.
ToXIC/FLAMMABLE
Dry cleaning solvent P-D-680 used
for cleaning parts, is toxic and
flammable.
Use only in well
ventilated areas. Wear protective
goggles and gloves. Do not smoke
or allow open flames or sparks in
areas where cleaning solvent is
used or stored.
Avoid contact
w i t h e y e s , s k i n o r c l o t h i n g . If
contact with eyes is made, flush
with cold water and seek medical
attention immediately. If contact
with skin or clothing is made,
f l u s h w i t h c o l d w a t e r . I f y ou
become dizzy while using cleaning
s o l v e n t , g e t f r e s h a ir
immediately.
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
U s e o n l y w i t h e f f e c t i v e c h i p
guarding and personal protective
equipment (goggles/shield,
g l o v e s , e t c . ) .
7.
Clean all other parts
solvent P-D-680. Dry
8.
I n s p e c t a l l p a r t s.
paragraph 2-9.
with cleaning
thoroughly.
R e f e r t o
Go to sheet 4
4-30
|