TM 10-3930-643-20
ENGINE, FUEL, EXHAUST AND COOLING TROUBLESHOOTING AND MAINTENANCE. (cont)
4 - 7.
Oil Sampling Valve (S/N 2001 and above). (Sheet 3 of 4)
CLEANING/INSPECTION
6.
7.
8.
TOXIC/FLAMMABLE
Dry cleaning
solvent P-D-680,
used for cleaning parts, is toxic
and flammable. Use only in well
ventilated
areas.
Wear
protective goggles and gloves.
Do not smoke or allow open flames
or sparks in areas where cleaning
solvent is used or stored. Avoid
c o n t a c t w i t h e y e s,
s k i n or
c l o t h i n g.
If contact with eyes
is made, flush with cold water
and
seek
medical
attention
immediately.
If contact with skin
or clothing is made, flush with
cold water. If you become dizzy
while using cleaning solvent, get
fresh air immediately.
COMPRESSED AIR HAZARD
Compressed air used for cleaning
purposes will not exceed 30 psi.
U s e o n l y w i t h e f f e c t i v e c h ip
guarding and personal protective
equipment (goggles/shield,
g l o v e s , e t c . ) .
Wipe oil sampling valve (2) or (3)
with clean cloth moistened with
cleaning solvent P-D-680.
Allow to
air dry.
C l e a n a l l p a r t s w i t h c l e a n i ng
s o l v e n t P - D - 6 8 0 . D ry
thoroughly
with compressed air.
R e f e r to
paragraph 2-8.
I n s p e c t a l l p a r t s .
R e f e r t o
paragraph 2-9.
Go to sheet 4
4-24
|