TM   10-3930-643-20 ENGINE,  FUEL,  EXHAUST  AND  COOLING  TROUBLESHOOTING  AND  MAINTENANCE.  (cont) 4 - 7. Oil   Sampling   Valve   (S/N   2001   and   above).   (Sheet   3   of   4) CLEANING/INSPECTION 6. 7. 8. •TOXIC/FLAMMABLE Dry   cleaning solvent   P-D-680, used   for   cleaning   parts,   is   toxic and   flammable.   Use   only   in   well ventilated areas. Wear protective   goggles   and   gloves. Do   not   smoke   or   allow   open   flames or   sparks   in   areas   where   cleaning solvent   is   used   or   stored.   Avoid c o n t a c t    w i t h    e y e s, s k i n    or c l o t h i n g. If   contact   with   eyes is   made,   flush   with   cold   water and seek medical attention immediately. If   contact   with   skin or   clothing   is   made,   flush   with cold   water.   If   you   become   dizzy while   using   cleaning   solvent,   get fresh   air   immediately. COMPRESSED AIR HAZARD Compressed   air   used   for   cleaning purposes   will   not   exceed   30   psi. U s e    o n l y    w i t h    e f f e c t i v e    c h ip guarding   and   personal   protective equipment     (goggles/shield, g l o v e s ,     e t c . ) . Wipe   oil   sampling   valve   (2)   or   (3) with   clean   cloth   moistened   with cleaning   solvent   P-D-680. Allow   to air   dry. C l e a n    a l l    p a r t s    w i t h    c l e a n i ng s o l v e n t    P - D - 6 8 0 .    D ry thoroughly with   compressed   air. R e f e r    to paragraph   2-8. I n s p e c t    a l l    p a r t s . R e f e r    t o paragraph   2-9. Go  to  sheet  4 4-24