CAUTION
TM 10-3930-643-10
2-18.
PREVENTIVE MAINTENANCE CHECKS AND SERVICES.-Continued
LEAKAGE DEFINITIONS FOR OPERATOR/CREW PMCS
Class I
Seepage of fluid (as indicated by wetness or
discoloration) not great enough to form drops.
Class II
Leakage of fluid great enough to form drops, but
not enough to cause drops to drip from the item
being
checked/inspected.
Class
III
Leakage
of
fluid
great
enough
to
form
drops
that
fall from the item being checked/inspected.
Equipment operation is
allowable with minor leakages
(Class I or II). Of course,
consideration must be given
to the fluid capacity in the item/system being checked/
inspected.
When operating with Class I or II leaks,
continue to check fluid levels as required on your PMCS.
Class III leaks should be reported to your supervisor or
organizational
maintenance.