2-3
TM
10-3930-643-10
2-2.
INSTRUMENT CONSOLE.-Continued
(c) Mechanical switch (12). Spring loaded, two position switch.
1 LOCK position (unmarked).
Prevents movement of main switch (A).
2 UNLOCK position.
Enables movement of main switch (A). Hold lever
in UNLOCK position and move main switch (3) to desired position.
(4) Bulb check switch (4).
Use to check operation of instrument panel
lights. Switch will return to OFF position when released. The oil pressure,
ground driven steering, and low air lights are not checked by this switch.
(5) Ether start switch (5).
Used in cold weather only to inject starting
fluid (ether) into the intake manifold to aid in starting the engine. Push the
button only while cranking the engine to inject a metered amount of starting
fluid.
(6) Front service light switch (6).
Controls the front service lights.
Light switch (3) must be in the SERVICE DRIVE position before using this
switch.
(7) Rear service light switch (7).
Controls the rear service lights.
Light switch (3) must be in the service drive position before using this
switch.
Never operate forklift without the engine fan switch on
except when water fording.
Failure to operate fan will
result in engine overheating and damage to engine.
Engage or disengage engine fan
operating at low idle.
(8) Engine fan switch (8). Controls
only when engine is
the engine fan.
Engine fan switch is
always ON except when fording because water will enter fan sweep.