TM 10-3930-638-24&P
4-4. TRANSMISSION MAINTENANCE (cont)
a. Torque Converter Group (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REASSEMBLY (cont)
33
b. Bearing spacer (19)
Position
(cont)
c. Reaction member
Install
(18)
d. Retaining ring(17)
Install
e. Locating ring (16)
Install
f. Turbine(15)
Install
WARNING
In following steps (34a through 34d), wear insulated gloves or
use tongs to handle impeller cover (10). Failure to do so could
cause you to burn your hands. Get medical aid if you burn your
hands.
34
Impeller
a. Impeller cover (10)
Heat
To 200-250 degrees F
cover
b. Retaining ring (12)
Position
In groove in impeller cover (10)
c. Retaining washer (14)
Install
d. Bearing (13)
Install
While impeller cover (10) is hot, press bear-
ing into position while spreading ears on
retaining ring (12). Align ring groove in
bearing with retaining ring (12) then re-
lease retaining ring. Check retaining
ring to be sure it is in full position in
groove
4-148
|