TM  10-3930-638-24&P 4-2.   ENGINE   MAINTENANCE   (cont) i. Oil Pump (cont). 8 Check STEP LOCATION ITEM ACTION REMARKS INSPECTION (cont) b.  Pump  gears Check Use feeler gage as shown and check pump (Cont) gears  to  body  radial  clearance.  Clearance shall not exceed 0.008 inch. Replace oil pump if clearance exceeds this dimension c. Pump gears Place plasti gage on pump gear. Install gasket (7), cover assembly (6), cap screw (2), and lock washer (3), Tighten cap screws to 6-8 pounds foot torque. Re- move cover assembly and measure plasti gage  to  obtain  gear  to  cover  clearance. Clearance shall not exceed 0.008 inch. Replace oil pump if clearance is greater than this dimension 9 Relief  valve  spring  (11) lnspect Check that free length is 2.125 inches and  that  load  required  to  compress  spring to 1.44 inches is 18-19 pounds. Replace if none of these conditions are met 10 Oil  pump Inspect Replace if screen torn, or if suction tube screen (1) bent, dented or cracked 11 Relief valve (12) Inspect Replace  if  damaged  or  distorted and spring retainer (10) REASSEMBLY 12 Oil  pump a. Relief valve (12) Install Closed end toward oil pump body  (13) b. Relief valve spring Install (11) c. Spring retainer (10) Install Closed  end  outward 4-72