TM 10-3930-638-24&P
4-2. ENGINE MAINTENANCE (cont)
i. Oil Pump (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
WARNING
Wear safety glasses when drying parts with compressed air. Fail-
ure to do so could cause serious injury to eyes and possible blind-
ness. If you hurt your eyes or if a foreign object is blown into
your eyes, seek medical attention immediately.
6
Oil pump screen (1)
Clean
Immerse in cleaning solvent P-D-680. Clean
all solidified lubricant/sludge from
screen and inside suction tube. Dry with
moisture free compressed air
7
All other parts
Clean
Use cleaning solvent P-D-680; dry with
moisture free compressed air or clean
cloths
INSPECTION
8
Oil pump
a. Pump drive
Check
Use feeler gage as shown and check pump
body (13)
gear
drive gear to oil pump body clearance.
Clearance shall not exceed 0.010 inch;
if clearance exceeds this dimension, re-
place oil pump
4-71
|