TM  10-3930-638-24&P 3-30.   HYDRAULIC   LIFT   SYSTEM   MAINTENANCE   (cont) d. Rotation Cylinder Assembly (cont). STEP LOCATION ITEM ACTION REMARKS DISASSEMBLY WARNING Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable.  Wear  protective  goggles  and  gloves  and  use  only  in  a well ventilated area. Avoid contact with skin, eyes, and clothes and don’t breathe vapors, Do not use near open flame or exces- sive heat and don’t smoke when using it. Failure to do so could cause serious injury. If you become dizzy while using cleaning solvent, get fresh air immediately, and get medical attention. If contact with skin or clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes with water immedi- ately,  and  obtain  medical  aid  immediately. 2 Rotation a.  Rotation  cylinder Clean all exterior Use  cleaning  solvent  P-D-680 cylinder assembly (8) surfaces assembly (8) b.  Two  lubrication Remove fittings (9) c.  Gland  assembly  (17) Loosen d. Rod (24), gland as- Remove as an sembly (17), and assembly piston assembly (12) e. Cap screw (10) and Remove washer (11) f. Piston assembly (12) Remove g.  Gland  assembly  (17) Remove 3 Piston  assembly a. Wear ring (13) Remove  and (12) discard b. Sealing ring (14) Remove  and discard c. O-ring (15) Remove  and discard 4 Gland assembly a. Plug (18) Remove only if (17) damaged b. O-ring (19) Remove  and discard c. Back-up ring (20) Remove  and discard d.  Wiper(21) Remove  and discard e. Seal (22) Remove  and discard 3-234