TM 10-3930-638-24&P
3-30. HYDRAULIC LIFT SYSTEM MAINTENANCE (cont)
a. Control Valve (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention, If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
26
All parts
Clean
Use cleaning solvent P-D-680. Dry
thoroughly. Be sure that bores in
housings are thoroughly clean
INSPECTION/REPAIR
27
Springs
Inspect
Replace if distorted, cracked or fatigue
signs are evident
28
spools
Inspect
Replace if finish is damaged or if bent
or damaged
29
Screws and plugs
Inspect
Replace if threads damaged in any way,
or corroded.
30
Housings
Inspect
Replace if bores damaged, cracked, internal
threads damaged, or internal wear is
evident
31
All other parts
Inspect
Replace if damaged, cracked, or distorted
LEFT COVER PLATE REASSEMBLY
NOTE
Lubricate all O-rings before reassembly with clean hydraulic oil
(refer to current lubrication order).
32
Relief plug (6)
a. O-ring (5)
Install
On plug (6)
b. Back-up washer (4)
Install
c. O-ring (3)
Install
d. Back-up washer (2)
Install
3-213
|