TM 10-3930-638-24&P
3-30. HYDRAULIC LIFT SYSTEM MAINTENANCE (cont)
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Operators com-
a. Control valve linkage
Disconnect
Para 2-56b, step 2
partment,
control valve
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
cent act with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
b. Tube fittings
Clean
Use clean cloth moistened with cleaning
solvent P-D-680 and remove all dirt and
grease
c. Tube fittings
Tag, disconnect
Para 2-56f(1), steps 1a, 1c, 1h, and 1j
and cap
a. Conntrol Valve (cont).
3-205
|