TM 10-3930-638-24&P
3-14. INSTRUMENT PANEL REPLACEMENT (cont)
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Operators
compartment
CLEANING
2
INSPECTION
3
4
INSTALLATION
5
Operators
compartment
a. Four nuts (1), lock
Loosen and
washers (2) and
remove
washers (3)
b. Four cap screws
Lift and
(4)
remove
c. Instrument panel
Lift and
(5)
remove
Use sling and hoist
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
con tact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
Wear safety glasses when drying parts with compressed air. Fail-
ure to do so could cause serious injury to eyes and possible blind-
ness. If you hurt your eyes or if a foreign object is blown into
your eyes, seek medical attention immediately.
All parts
Clean
Use cleaning solvent P-D-680. Dry thor-
oughly with compressed air
Nuts (1), washers (2
Inspect
Replace if worn, or if threads damaged
and 3) and cap
screws (4)
Instrument panel (5)
Inspect
Repair broken welds or cracks by welding.
Replace if severely cracked or damaged
a. Instrument
Position
In operators compartment, with frame
panel (5)
and instrument panel mounting holes
aligned
b. Four cap screws (4)
Install and
Until instrument panel is securely mounted
washers (3), lock
tighten
washers (2) and
nuts (1)
3-116
|