TM  10-3930-638-24&P 3-13.  STARTER  AND  SOLENOID  REPAIR  (cont) STEP LOCATION ITEM ACTION REMARKS REASSEMBLY  (cont) End frame a. Wick (6) b. Pipe plug (5) Drive hous- a. End frame (4) ing (53) b. Two through bolts (3) c. Field coil con- nector (2) d. Starter and sole- noid Lubricate  and install Install Lubricate  and position Install  and tighten Insulate Connect Saturate with engine oil before installing Apply light coat of lubricant to frame bushing; then slide on armature shaft and push against field frame (7) Until end frame (4) is securely mounted Wrap with electrical tape To test circuit as shown CAUTION Check  pinion  clearance  quickly  to  avoid  overheating  and  damag- ing  solenoid  windings. e. Jumper lead Momentarily con- From solenoid M terminal to starter case nect (to shift pinion into cranking position) 3-112