TM  10-3930-636-24&P 3-13.   STARTER   AND   SOLENOID   REPAIR   (cont) STEP LOCATION ITEM ACTION REMARKS DISASSEMBLY  (cont) (cont) CLEANING 6 h. Four screws (43) Remove i. Four nuts (44) Remove j. Four lock washers Remove  and (45) discard k. Two control assem- Remove blies  (46) NOTE Do not remove screw (47), lock washer (48), connector (2) or grommet  (49)  unless  replacement  is  required. l. Screw (47) Remove m. Lock washer (48) Remove n. Connector (2) Remove o. Grommet (49) Remove NOTE Do not remove field coil assembly (52), pole shoes (51) or screws (50)  unless  parts  need  replacement. p. Eight screws (50) Remove q. Four pole shoes (51) Remove r.  Field  coil  assembly Remove  and (52) release Armature (10), drive Clean Wipe with a clean, dry, lint-free cloth only. assembly’  15),  solenoid Do not use cleaning solvent switch (24), brushes (39), grommet (49) and coil assembly (52) WARNING Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable.  Wear  protective  goggles  and  gloves  and  use  only  in  a well ventilated area. Avoid contact with skin, eyes, and clothes and don’t breathe vapors. Do not use near open flame or exces- sive heat and don’t smoke when using it. Failure to do so could cause serious injury. If you become dizzy while using cleaning solvent, get fresh air immediately, and get medical attention. If contact with skin or clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes with water immedi- ately,  and  obtain  medical  aid  immediately. 3-106