TM 10-3930-636-24&P
3-13. STARTER AND SOLENOID REPAIR (cont)
STEP
LOCATION
ITEM
ACTION
REMARKS
DISASSEMBLY (cont)
(cont)
CLEANING
6
h. Four screws (43)
Remove
i. Four nuts (44)
Remove
j. Four lock washers
Remove and
(45)
discard
k. Two control assem-
Remove
blies (46)
NOTE
Do not remove screw (47), lock washer (48), connector (2) or
grommet (49) unless replacement is required.
l. Screw (47)
Remove
m. Lock washer (48)
Remove
n. Connector (2)
Remove
o. Grommet (49)
Remove
NOTE
Do not remove field coil assembly (52), pole shoes (51) or screws
(50) unless parts need replacement.
p. Eight screws (50)
Remove
q. Four pole shoes (51)
Remove
r. Field coil assembly
Remove and
(52)
release
Armature (10), drive
Clean
Wipe with a clean, dry, lint-free cloth only.
assembly 15), solenoid
Do not use cleaning solvent
switch (24), brushes
(39), grommet (49)
and coil assembly (52)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
3-106
|