TM 10-3930-638-24&P
3-12. ALTERNATOR REPAIR (cont)
STEP
LOCATION-
ITEM
ACTION
REMARKS
TESTING (cont)
14
15
Stator (4)
Test
Rotor (23)
Test
Use an ohmmeter to check. Connect test
prods as shown. If meter reading is
low when connected to any stator
lead and frame, the windings are
grounded. If the meter reading is high
when connected between each pair
of stator leads, the windings are open.
If stator winding is grounded or open
or if evidence of short is observed, re-
place stator
Use 110 volt test lamp. Connect test lamp
from rotor slip ring to rotor shaft. If lamp
lights, the field windings are grounded.
Connect test lamp leads to each rotor slip
ring. If lamp fails to light, field windings
are open. Connect ammeter and battery
to rotor as shown. If ammeter indicates
more than 4.0 to 4.5 amperes, rotor field
windings are shorted. If field windings are
grounded, open or have shorted, replace
rotor
REASSEMBLY
16
Drive end
a. Grease slinger
Install
frame (1)
washer (30)
b. Inside of bearing
Back up
Use camshaft gear remover tool
area on end
frame (1)
c. Ball bearing (29)
Install
Press on closed end of bearing until flush
with end frame housing
d. Ball bearing re-
install
Use valve guide installer tool until retainer
tainer plate (28)
seats against bearing (29)
e. Three screws (27)
Install and
Until retainer (28) is securely mounted
tighten
3-99
|