TM 10-3930-638-24&P
2-56. HYDRAULIC LIFT SYSTEM MAINTENANCE (cont)
b. cControl Levers and Linkages (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Operators com-
Four knobs (1)
Remove
Unscrew from levers
partment,
instrument
panel, top
2
Operators com-
a. Four cotter pins (2)
Remove from
partment,
control valve
instrument
spools
panel, bottom
b. Four clevis pins (3)
Remove
c. Assembled control
Remove as an
Place on work bench
levers
assembly from
bottom of
instrument
panel
3
Assembled
a. Four cotter pins (4)
Remove
control levers
b. Four clevis pins (5)
Remove
c. Eight valve links
Remove
(6 and 7)
d. Retaining ring (8)
Remove
e. Tilt control lever (9)
Remove
f. Washer (10)
Remove
g. Lift control lever (11)
Remove
h. Washer (12)
Remove
i. Shift control lever (13)
Remove
j. Washer (14)
Remove
k. Rotate control lever (15) Remove
1. Retaining ring (16)
Remove
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immed-
iately, and obtain medical aid immediately.
4
All parts
Clean
Use cleaning solvent P-D-680
Used as required
Used as required
Used as required
2-397
|