TM 10-3930-638-24&P
2-52. FRAME AND TOWING ATTACHMENTS MAINTENANCE (cont)
a. Roll Over Protective Structure (cont).
Use hoist
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Operators com-
a. Three wire leads
Tag and disconnect Located at bottom of ROPS, two on left,
partment
one on right
b. Roll over protective
Secure
Attach hoist
structure (9)
c. Two nuts (1), washers
Remove
(2), reinforcing plates
(3), washers (4), and
cap screws (5)
d. Two nuts (6), lock
Remove
washers (7), and
cap screws (8)
e. Roll over protective
Remove
structure (9)
f. Two nuts (10), lock
Remove
washers (11), washers
(12), and cap
screws (13)
g. Two brackets (14)
Remove
NOTE
Dont perform following step unless inspection indicates re -
placement of canopy headlining (15) is necessary.
h. Canopy headlining
Remove only if
(15)
damaged
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immed-
iately, and obtain medical aid immediately.
2
ALL parts
Clean
Use cleaning solvent P-D-680. Dry
thoroughly
2-356 CHANGE 2
|