TM 10-3930-638-24&P
2-38. TRANSMISSION MAINTENANCE (cont)
b. Transmission Linkage Controls (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
CLEANING
8
Cables (53, 54) and con-
Clean
Use clean diesel fuel. Dry thoroughly
trol lever balls (16, 23)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immed-
iately, and obtain medical aid immediately.
9
All other parts
Clean
Use cleaning solvent P-D-680. Dry
thoroughly
INSPECTION/REPAIR
10
Cables (53, 54)
Inspect
Replace if cracked, worn, damaged,
twisted or distorted
11
Spring (10)
Inspect
Replace if cracked, worn, damaged,
distorted or permanently set
12
All other parts
Inspect
Replace if cracked, worn, damaged,
distorted, or missing or damaged threads
INSTALLATION/REPLACEMENT
13
Operators com-
a. Two cables (53, 54)
Position
partment, under
b. Two tie straps (52)
Install
floor panel
c. Two cable clamps (51)
Position
d. Two cable hold down
Position
plates (50)
e. Three spacers (47)
Install
f. Clamp (49)
Position
g. Washer (55)
Position
h. Four cap screws (48)
Install
i. Four lock washers (46) Install
j. Four nuts (45)
Install
14
Transmission
a. Cable bracket (44)
Position
b. Two lock washers (43)
Position
c. Two cap screws (42)
Install
d. Stud (41)
Install
e. Spacer (40)
Position
2-217
|