TM 10-3930-638-24&P
2-38. TRANSMISSION MAINTENANCE (cont)
a. Transmission Servicing and Inspection (cont).
(3) Air Breather (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Transmission
Air breather
Remove
torque converter
housing, top
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or exces-
sive heat and dont smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately. and obtain medical aid immediately.
2
Air breather
Clean
Use cleaning solvent P-D-680
INSPECTION
3
Air breather
Inspect
Replace if damaged or clogged
INSTALLATION
4
Transmission
Air breather
Install
torque converter
housing, top
2-206
|