TM  10-3930-638-24&P 2-38.   TRANSMISSION   MAINTENANCE   (cont) a. Transmission Servicing and Inspection (cont). (3) Air Breather (cont). STEP LOCATION ITEM ACTION REMARKS REMOVAL 1 Transmission Air breather Remove torque  converter housing, top CLEANING WARNING Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable.  Wear  protective  goggles  and  gloves  and  use  only  in  a well ventilated area. Avoid contact with skin, eyes, and clothes and don’t breathe vapors. Do not use near open flame or exces- sive heat and don’t smoke when using it. Failure to do so could cause serious injury. If you become dizzy while using cleaning solvent, get fresh air immediately, and get medical attention. If contact with skin or clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes with water immedi- ately. and obtain medical aid immediately. 2 Air breather Clean Use cleaning solvent P-D-680 INSPECTION 3 Air breather Inspect Replace  if  damaged  or  clogged INSTALLATION 4 Transmission Air breather Install torque  converter housing, top 2-206