TM 10-3930-638-24&P
2-30. LIGHT SYSTEMS MAINTENANCE (cont)
a. Flood Lights (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Front or rear
a. Rubber gasket (1)
Pull inserts
From cut outs in housing (9)
b. Rubber gasket (1)
Pull and remove
From housing (9) and lamp (3)
c. Wire leads (2)
Tag, grasp and
From lamp (3); set lamp (3) aside
pull
d. Connector (4)
Grasp and pull
From harness lead
e. Seal (5)
Grasp and pull
Not used on instrument panel-mounted
from nut (6)
flood lights or rear flood lights
f. Nut (6), lock washer
Remove
Support housing (9)
(7) and washer (11)
g. Housing and spacer
Remove
Seal (8) not used on instrument panel-
(9) and seal (8)
mounted flood lights
h. Grommet (10)
Remove
From ROPS
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or
excessive heat and dont smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using
cleaning solvent, get fresh air immediately, and get medical
attention. If contact with skin or clothes is made, flush with large
amounts of water. If contact with eyes is made, wash eyes with
water immediately, and obtain medical aid immediately.
2
Wire connectors and
Clean
Use cleaning solvent P-D-680 on
terminals
connectors and terminals only
3
Gasket (1), seals (5 and 8) Clean
Wipe with a clean, dry cloth
and grommet (10)
WARNING
Wear safety glasses when drying parts with compressed air.
Failure to do so could cause serious injury to eyes and possible
blindness. If you hurt your eyes or if a foreign object is blown
into your eyes, seek medical attention immediately.
4
Housing (9) and
Clean
Use cleaning solvent P-D-680.
hardware (6, 7 and 11)
Dry thoroughly with compressed air
INSPECTION
5
All hardware
Inspect
Replace if worn, or if threads damaged
CHANGE 2 2-145
|