TM    10-3930-638-24&P 2-29. AUXILIARY PANEL MAINTENANCE (cont) a. Slave Receptacle (cont). STEP LOCATION ITEM ACTION REMARKS INSPECTION 4 All hardware Inspect Replace if worn, or if threads damaged 5 Cables (2 and 3) Inspect Replace if insulation frayed, or if conductors  broken 6 Receptacle  (7)  and Inspect Replace if threads damaged, or if cover (10) receptacle  terminals  damaged 7 Rubber  insulators  (8 Inspect Replace  if  cracked  or  deteriorated and 9) INSTALLATION/   REPLACEMENT 8 Left hood support a. Cover (10) Install On  receptacle  (7) plate,  top b. Rubber insulators (8 Position On left side panel and 9) and receptacle (7) c. Four screws (6) flat Install  and washers (5) and tighten nuts  (4) d. Cables (2 and 3) and Install and two cap screws (1) tighten e.  Cable  connectors  and Seal cap screws (1) On  receptacle  (7) Use silicone rubber sealer 2-141