TM  10-3930-638-24&P 2-29. AUXILIARY PANEL MAINTENANCE (cont) a. Slave Receptacle (cont). STEP LOCATION ITEM ACTION REMARKS REMOVAL 1 Left hood support a. Two cap screws (1) and Remove From  slave  receptacle  (7) plate,  top cables (2 and 3) b. Four nuts (4), flat Remove Support  receptacle  (7) washers (5) and screws (6) c.  Receptacle  (7)  and Remove From left side panel rubber insulators (8 and 9) d. Cover (10) Unscrew and From receptacle (7) remove CLEANING WARNING Dry cleaning solvent (P-D-680), used to clean parts is toxic and flammable. Wear protective goggles and gloves and use only in a well ventilated area. Avoid contact with skin, eyes, and clothes and don’t breathe vapors. Do not use near open flame or excessive heat and don’t smoke when using it. Failure to do so could cause serious injury. If you become dizzy while using cleaning  solvent,  get  fresh  air  immediately,  and  get  medical attention. If contact with skin or clothes is made, flush with large amounts of water. If contact with eyes is made, wash eyes with water  immediately,  and  obtain  medical  aid  immediately. 2 Cable connectors and Clean Use cleaning solvent P-D-680 on receptacle  terminals connectors  and  terminals  only WARNING Wear safety glasses when drying parts with compressed air. Failure to do so could cause serious injury to eyes and possible blindness. If you hurt your eyes or if a foreign object is blown into  your  eyes,  seek  medical  attention  immediately. 3 Cover (10) and all Clean Use  cleaning  solvent  P-D-680. hardware Dry thoroughly with compressed air 2-140

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business