TM 10-3930-638-24&P
2-29. AUXILIARY PANEL MAINTENANCE (cont)
a. Slave Receptacle (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
REMOVAL
1
Left hood support a. Two cap screws (1) and Remove
From slave receptacle (7)
plate, top
cables (2 and 3)
b. Four nuts (4), flat
Remove
Support receptacle (7)
washers (5) and
screws (6)
c. Receptacle (7) and
Remove
From left side panel
rubber insulators (8
and 9)
d. Cover (10)
Unscrew and
From receptacle (7)
remove
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and dont breathe vapors. Do not use near open flame or
excessive heat and dont smoke when using it. Failure to do so
could cause serious injury. If you become dizzy while using
cleaning solvent, get fresh air immediately, and get medical
attention. If contact with skin or clothes is made, flush with large
amounts of water. If contact with eyes is made, wash eyes with
water immediately, and obtain medical aid immediately.
2
Cable connectors and
Clean
Use cleaning solvent P-D-680 on
receptacle terminals
connectors and terminals only
WARNING
Wear safety glasses when drying parts with compressed air.
Failure to do so could cause serious injury to eyes and possible
blindness. If you hurt your eyes or if a foreign object is blown
into your eyes, seek medical attention immediately.
3
Cover (10) and all
Clean
Use cleaning solvent P-D-680.
hardware
Dry thoroughly with compressed air
2-140
|